Ceiling Batten Dimensions
The steel beam dimensions for the Ceiling Batten section can be seen in the table. The depth of the section is 22 mm. The width of the section is 22 mm.
| Dimension | Value |
|---|---|
| Depth | 22 mm |
| Left Flange Width | 12 mm |
| Right Flange Width | 12 mm |
| Top Width | 34 mm |
| Thickness | 0.42 mm |
| Fillet Radius | 0.42 mm |
| Lip Depth | 0 mm |
| Hat Angle | 17.7 mm |
| Lip Angle | 0 mm |
Ceiling Batten Section Properties
The Ceiling Batten section has an area of 43.2mm2. The below table outlines the Ceiling Batten section properties including the torsion constant as well as moment of inertia and plastic modulus properties.
| A | Izp | Iyp | rz | ry | J | Iw |
|---|---|---|---|---|---|---|
| 43.2 mm2 | 3560 mm4 | 16000 mm4 | 9.09 mm | 18.3 mm | 2.54 mm4 | 450000 mm6 |
Materials and Design Standards Ceiling Batten
This section is typically designed using the design standard AS 4600-2005 and is manufactured using a cold formed process as it is a steel section.