Cyclonic Roof Batten Dimensions
The steel beam dimensions for the Cyclonic Roof Batten section can be seen in the table. The depth of the section is 40 mm. The width of the section is 40 mm.
| Dimension | Value |
|---|---|
| Depth | 40 mm |
| Left Flange Width | 15 mm |
| Right Flange Width | 15 mm |
| Top Width | 40 mm |
| Thickness | 0.75 mm |
| Fillet Radius | 0.75 mm |
| Lip Depth | 7.07 mm |
| Hat Angle | 16.38 mm |
| Lip Angle | 45 mm |
Cyclonic Roof Batten Section Properties
The Cyclonic Roof Batten section has an area of 120mm2. The below table outlines the Cyclonic Roof Batten section properties including the torsion constant as well as moment of inertia and plastic modulus properties.
| A | Izp | Iyp | rz | ry | J | Iw |
|---|---|---|---|---|---|---|
| 120 mm2 | 29500 mm4 | 68900 mm4 | 15.7 mm | 24 mm | 22.5 mm4 | 8840000 mm6 |
Materials and Design Standards Cyclonic Roof Batten
This section is typically designed using the design standard AS 4600-2005 and is manufactured using a cold formed process as it is a steel section.