WA Ceiling Batten Dimensions

The steel beam dimensions for the WA Ceiling Batten section can be seen in the table. The depth of the section is 25 mm. The width of the section is 25 mm.

0 mm 12 mm 27 mm 12 mm 25 mm 0.42 mm
Dimension Value
Depth 25 mm
Left Flange Width 12 mm
Right Flange Width 12 mm
Top Width 27 mm
Thickness 0.42 mm
Fillet Radius 0.42 mm
Lip Depth 0 mm
Hat Angle 24.5 mm
Lip Angle 0 mm

WA Ceiling Batten Section Properties

The WA Ceiling Batten section has an area of 43.4mm2. The below table outlines the WA Ceiling Batten section properties including the torsion constant as well as moment of inertia and plastic modulus properties.

A Izp Iyp rz ry J Iw
43.4 mm2 4430 mm4 13300 mm4 10.1 mm 17.5 mm 2.55 mm4 500000 mm6

Materials and Design Standards WA Ceiling Batten

This section is typically designed using the design standard AS 4600-2005 and is manufactured using a cold formed process as it is a steel section.